1. Electrical specifications

Standard conditions Basic test conditions

Room temperature :5 ~ 35℃

Temperature: 20 plus or minus 2 ℃

General humidity :45 ~ 85%

Humidity :63 ~ 67%

Normal pressure :86 ~ 106kPa

Normal pressure :86 ~ 106kPa

2. Application circuit

1.png

3.frequnency Response

2.png

4. Reliability test

All tests shall be carried out in the same batch of tests in the sequence listed. The sensitivity should be within ±3dB of the initial sensitivity after 2 hours of restoration at 20℃

Temperature test: Sensitivity should be within ±3 dB of the initial value after 200 hours of exposure at 60°C. After 200 hours of exposure at -25°C, the sensitivity should be within ±3 dB of the initial value.

Humidity test: After exposure for 200 hours at 60±3℃ and 90~95% relative humidity, the sensitivity should be within ±3 dB of the initial value

Temperature cycle test: 30 minutes of exposure at -25°C, 10 minutes at 20°C, 30 minutes at 60°C, and 10 minutes at 20°C. Sensitivity should be within the initial value ±3 dB after 15 cycles.

Vibration test: To ensure that the vibration does not affect the use, 10 Hz to 50 Hz at a full amplitude of 1.52 mm for 1 minute, at 3 large angles for 2 hours.

Drop test: In order to ensure that the test microphone in the package falls off and does not affect its use, the 3 sides of the package are dropped from a height of 1.5 meters on the cement floor for 12 cycles.